Measurements of pulmonary mechanics prior to the elective extubation of neonates

Pediatr Pulmonol. 1990;9(4):238-43. doi: 10.1002/ppul.1950090409.

Abstract

We measured total respiratory system compliance (CRS) and resistance (RRS) by the passive expiratory flow technique prior to the elective extubation of 61 neonates with a history of respiratory distress syndrome. Successful trials of extubation were characterized by a higher mean value of CRS when compared to trials that led to reintubation (1.52 vs. 1.10 mL/cm H2O, P = 0.004). Low values of CRS (0.9 mL/cm H2O or less) were invariably associated with extubation failure, whereas high values of CRS (1.3 mL/cm H2O or greater) were associated with extubation success in 94% of patients. A higher mean value of RRS was recorded in the group of infants who failed extubation when compared to those who were successful (0.22 vs. 0.17 cm H2O/mL/s, P = 0.042). We propose that measurements of pulmonary mechanics, particularly CRS, may be useful in identifying infants who will be at risk for extubation failure.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Airway Resistance
  • Body Weight
  • Humans
  • Infant, Newborn
  • Lung Compliance
  • Respiratory Distress Syndrome, Newborn / physiopathology
  • Respiratory Distress Syndrome, Newborn / therapy
  • Respiratory Mechanics*
  • Ventilator Weaning*