Estimation of extracellular fluid volume by bromide dilution in infants less than 1000 grams birth weight

Early Hum Dev. 1991 Nov;27(1-2):19-24. doi: 10.1016/0378-3782(91)90024-w.

Abstract

We measured extracellular fluid volume by bromide dilution within 12 h of birth in 32 infants less than 1000 g birth weight. Mean (+/- S.D.) birth weight and gestational age were 763 +/- 123 g and 26 +/- 1 week, respectively. Mean extracellular fluid volume was 360 +/- 86 ml (477 +/- 107 ml/kg). These results are similar to extracellular fluid volume estimates from previous carcass analysis data. Wide variability is observed with both methods suggesting that biologic variability may be important.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Body Weight
  • Bromides*
  • Extracellular Space*
  • Female
  • Gestational Age
  • Humans
  • Infant, Low Birth Weight / physiology*
  • Infant, Newborn
  • Injections, Intravenous
  • Male
  • Plasma / chemistry
  • Regression Analysis
  • Sodium Compounds*
  • Sodium*

Substances

  • Bromides
  • Sodium Compounds
  • Sodium
  • sodium bromide