Table 2

Depth of compressions and coefficient of variation (COV) utilising a 3:1 compression to ventilation ratio for 2 min using the two-thumb compared with the two-finger technique

Two-thumb 3:1 (2 min)Two-finger 3:1 (2 min)p Value
Depth (mm)29±5.423.7±5.80.0009
Variability (COV)6.1±2.99.8±3.10.00002