Table 2

 Temperature outcomes for preterm infants (23–27 weeks) transported via incubator or radiant warmer (median values with interquartile ranges are shown where appropriate)

IncubatorRadiant Warmerp value
Number3032
Below 36.5°C (%)10 (33)7 (22)0.4
Above 37.5°C (%)2 (6.7)1 (3.1)0.60
Outside range (36.5–37.5)°C (%)12 (40)8 (25)0.28
Below 36.0°C (%)6 (20)3 (9.4)0.29
Outside range (36.0–37.5)°C (%)8 (26.7)4 (12.5)0.20
Admission temperature (IQ range)°C36.8 (36.2–37.3)36.8 (36.5–37.1)0.81
Time to admission (min)17 (14–18.3)14.5 (11–19.8)0.21
Coefficient of variation0.460.280.51
Maternal temperature (°C)36.7 (36.2–37.2)36.9 (36.4–37.2)