TY - JOUR T1 - Contrast study in umbilical venous line extravasation JF - Archives of Disease in Childhood - Fetal and Neonatal Edition JO - Arch Dis Child Fetal Neonatal Ed DO - 10.1136/archdischild-2020-321081 SP - fetalneonatal-2020-321081 AU - Susan Rutendo Kamupira AU - James Dexter Tarr AU - Minju Kuruvilla Y1 - 2021/02/04 UR - http://fn.bmj.com/content/early/2021/02/03/archdischild-2020-321081.abstract N2 - A preterm infant born at 25 weeks’ gestation, birth weight 730 g, had an umbilical venous catheter (UVC) inserted on day 1. The line bled and flushed freely at 5 cm and would not sample beyond this position. Supine abdominal X-ray (AXR) showed vertical position of the line with the tip at T11–T12. This was recognised as a suboptimal position but attempts to secure intravenous access with a percutaneous long line was unsuccessful. The UVC remained in situ and was … ER -