Article Text
Abstract
Aim To compare thyroid function tests in preterm neonates (<30 weeks and >48 hour old) exposed to iodine-based contrast with controls and ascertain the certainty of peripherally inserted central catheter (PICC) tip position.
Methods Infants requiring a PICC were randomised to receive 0.3 mL of iodine-containing contrast or normal saline. The primary outcome was the difference in thyroid-stimulating hormone (TSH) levels on day 14 post PICC insertion and on day 28 of life.
Results 41 infants were randomised with no significant differences in TSH level (mIU/L) at day 14 post PICC insertion (3.1 vs 2) or on day 28 of life (2.2 vs 1.7). The PICC tip was more easily localised in the contrast group (85% vs 55%). Urinary iodine levels were significantly increased in the contrast-exposed group.
Conclusion Use of contrast did not suppress subsequent thyroid function and helped visualise the PICC tip with more certainty.
Clinical trial registration number ACTRN12614000560695, pre-result.
- preterm
- iodine
- thyroid function
- percutaneous catheter
Statistics from Altmetric.com
Linked Articles
- Fantoms