Article Text

Download PDFPDF
Examining the effects of a targeted noise reduction program in a neonatal intensive care unit

Abstract

Objectives To determine whether implementation of a noise reduction policy followed by the addition of direct audit and feedback reduces noise levels in a tertiary-level neonatal intensive care unit (NICU).

Study design Noise level data was collected in three phases: (1) baseline (preintervention), (2) immediately postimplementation of our noise reduction policy, (3) postunveiling of direct audit and feedback mechanism.

Setting A level 3 NICU in Ontario, Canada.

Interventions Noise reduction policy and a direct audit and feedback mechanism.

Main outcome measures Average noise level.

Results The baseline level of noise in our unit consistently exceeds guidelines with an average baseline noise of 49 dB (±1.4). Our intervention resulted in a significant reduction in noise levels for one of the four areas in our NICU [−1.06 dB (−1.52, −0.6)], with a trend towards reduction in a second area (−0.21 dB (−0.6, 0.18)). Unexpectedly, two other areas experienced a significant increase in noise (2.05 dB (1.18, 2.94); 0.85 dB (0.11, 1.59)).

Conclusions The baseline noise in the NICU consistently exceeds guidelines, but reductions in noise levels are achievable. Nonetheless, more work is needed to find the optimal NICU design and noise reduction strategy.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.