Article Text

Download PDFPDF

Fetal diagnosis of congenital heart disease by telemedicine
Free
  1. Brian A McCrossan1,
  2. Andrew J Sands1,
  3. Theresa Kileen2,
  4. Chris R Cardwell3,
  5. Frank A Casey1
  1. 1Department of Paediatric Cardiology, Royal Belfast Hospital for Sick Children, Belfast, UK
  2. 2Department of Radiology, Altnagelvin Area Hospital, Derry, UK
  3. 3Centre for Public Health, The Queen's University of Belfast, Belfast, UK
  1. Correspondence to Dr Brian A McCrossan, Department of Paediatric Cardiology, Royal Belfast Hospital for Sick Children, Falls Road, Belfast BT 12 6BE, UK; brianmccrossan{at}doctors.org.uk

Abstract

Objectives This study aimed to evaluate the feasibility, accuracy and user acceptability of performing remote fetal echocardiograms (FEs).

Setting A regional fetal cardiology unit and a district general hospital (DGH).

Design A prospective study over 20 months. An initial FE was performed by a radiographer in the DGH (D1) followed by a second FE transmitted to the regional centre, in real time, via a telemedicine link with live guidance by a fetal cardiologist (D2). A FE was performed later at the regional centre (D3, reference standard). Structured questionnaires were employed to evaluate the technical quality of each tele-link and the radiographers' confidence at performing FE.

Results 69 remote FEs were performed and showed 58 normal hearts and 11 with congenital heart disease (CHD). D2 was accurate in 97% of cases compared with D3 (κ score=0.89) indicating excellent agreement. All tele-links connected at first attempt with a mean study time = 13.9 min. Overall tele-link quality was rated highly (median=4/5). In 94% of tele-links, at least 11/12 components of the FE were confidently assessed. The mean composite radiographer's questionnaire score increased significantly during the study period (p<0.05).

Conclusions To date this is the largest study of its kind. CHD can be confidently diagnosed and excluded by remote FE. Radiographers report increased confidence and proficiency following involvement in real-time telemedicine. This application of telemedicine could improve access to fetal cardiology and support radiographers screening for CHD.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Introduction

Fetal diagnosis of congenital heart disease (CHD) varies across countries and regions. Prior to specific training schemes, most regions report a baseline detection rate of approximately 25%.1,,6 In the UK, the best opportunity of screening for CHD is at the routine fetal anomaly ultrasound scan which is performed by radiographers with little experience and training in cardiac evaluation.1 Although training schemes have been shown to significantly improve prenatal detection of CHD, there is evidence that the beneficial effect diminishes with time.4 5 7 Effective screening for CHD may profit from additional strategies to provide ongoing support and opportunistic training for radiographers. Such schemes may partly compensate for a lack of exposure to CHD.8,,11

Real-time fetal tele-echocardiography offers the possibility of earlier diagnosis of CHD and support for obstetric sonographers. The authors hypothesised that telemedicine could assist in keeping patients close to home while also increasing access to specialist opinion. Tele-echocardiography in neonates has proved very successful in diagnosing and excluding CHD.12,,18 The British Congenital Cardiac Association (BCCA) recommends that all tertiary congenital heart centres have telemedicine links with district general hospitals (DGHs) in their region.19 As fetal echocardiography is significantly different from trans-thoracic echocardiography1 20 and no acceptable transmission bandwidth has been clearly established for conducting fetal tele-echocardiography, a separate evaluation is necessary. The authors have published extensively on the role of telemedicine in paediatric cardiology and sought to extend this technology to fetal cardiology.13 21,,24

What is already known on this topic

  • Congenital heart disease (CHD) is accurately diagnosed and excluded in neonates by transmission of echocardiographic images across a telemedicine link.

  • Transmitting fetal echocardiographic images, captured by a fetal cardiologist, across a real-time telemedicine link is feasible and accurate.

What this study adds

  • Fetal tele-echocardiography involving obstetric sonographers is feasible and reliable.

  • CHD is accurately diagnosed and excluded in fetuses by transmission of echocardiographic images across a telemedicine link.

  • Obstetric sonographers are very satisfied with and appreciate real-time fetal tele-echocardiography facilitated by a fetal cardiologist.

This study aimed to evaluate the feasibility, technical quality and diagnostic accuracy of fetal tele-echocardiography. It also sought to assess radiographers' opinions on the value of a fetal tele-cardiology service.

Methods

The study was conducted at the Royal Belfast Hospital for Sick Children, and Altnagelvin Area Hospital (ALT). Ethical approval was obtained from the Central Office for Research Ethics Committees (COREC) and informed consent obtained from all study participants. Consecutive eligible patients were invited to participate in the study. Inclusion criteria mirrored the referral criteria to our fetal cardiology service (table 1).

Table 1

Study inclusion criteria

The study protocol is summarised in figure 1. Two sessions per week were potentially available for tele-links and additional slots were created for urgent cases. The tele-links were planned to coincide with the fetal anomaly scan when possible. Teleconferences were transmitted in real-time via ISDN6. The hands-on fetal echocardiogram (FE) is considered the reference standard. Following each FE, the parents were informed of the diagnosis, what future management was required and had the opportunity to ask questions.

Figure 1

Study protocol. DGH, district general hospital.

FEs were performed using an ATL HDI 5000 ultrasound scanner (Advanced Technology Laboratories, Bothell, Washington, USA) which was replaced by a GE Voluson 730 4D (General Electric, Milwaukee, Wisconsin, USA) (at both ALT and regional unit). Both ultrasound scanners have a fetal cardiology package offering two-dimensional echocardiography, M-mode, pulsed wave and continuous wave Doppler and colour Doppler. At both sending and receiving sites, a Tandberg 880 (Tandberg, Lysaker, Norway) videoconferencing unit was employed.

Radiographer questionnaire

A structured Likert scale questionnaire was completed by the obstetric sonographers involved in this study. Questions related to confidence in fetal echocardiography and attitudes towards telemedicine consultations (table 2). The questionnaire was completed at the start and end of the study period.

Table 2

Radiographers' attitudes to fetal echocardiography and involvement in the Fetal Echocardiography Telemedicine Study

Statistical analysis

Qualitative assessment was measured using a five-point Likert scale (5, very good; 4, good; 3, average; 2, poor; 1, very poor) and again expressed as median (IQR). Diagnostic accuracy was calculated using a coefficient of agreement. Comparisons of tele-consultation quality and radiographers' attitudes were carried out using the appropriate non-parametric test. Statistical analysis was performed using Windows SPSS Version 14.0.

Results

Over 20 months, 67 pregnant women were recruited to the study. No patients refused consent. The median age of the study group was 31.3 years (range = 17.1–40.8 years, IQR 27.1–35.4 years). The median gestational age at the time of the tele-link was 23 weeks (range = 21–26 weeks, IQR 23–25 weeks). The fetal tele-echocardiograms were performed at this relatively late gestational age because this is the time that fetal anomaly scans are routinely performed in Northern Ireland.

Sixty-nine fetal tele-echocardiograms were performed on 67 women during the study period. There was one set of twins and a fetal tele-echocardiogram was repeated on one patient. One patient did not attend for hands-on FE and this has been taken into consideration when evaluating diagnostic accuracy. The timing of the three FEs along with the feasibility and quality of fetal tele-echocardiograms are shown in table 3.

In 50/69 (72%) cases all 12 aspects of the FEs were confidently assessed from the transmitted images. At least 11/12 structures were confidently assessed in 94% of cases. The most difficult structures to confidently assess were the ventricular septum (84% success) and pulmonary venous connections (84% success) table 4.

Table 3

Feasibility and quality of remote fetal tele-echocardiograms

Table 4

Frequency of confidently assessing individual aspects of fetal echocardiogram

In 19/69 (28%) cases the quality of the transmitted image was adversely affected by a range of factors relating to the fetal lie, obstructing limbs twin pregnancy and maternal obesity. Picture quality was rated as significantly lower in fetal tele-echocardiograms affected by these problems (median Likert score = 3.5/5 vs 4/5, p<0.01 (Mann–Whitney U test)).

Using the ‘hands-on’ FE as the reference standard, 58/69 (84%) FEs demonstrated normal fetal hearts. In 11 (16%) cases the FE was not normal with eight cases of major CHD including three duct-dependent lesions. Two patients had common arterial trunk, three had echogenic foci on the left atrio-ventricular valve. Critical aortic stenosis, Ebstein's anomaly, coarctation of aorta, double outright right ventricle, pulmonary atresia/ventricular septal defect (VSD) and complete atrio-ventricular septal defect were diagnosed in one patient each.

Diagnostic accuracy

The initial FE (D1) agreed with the ‘hands-on’ FE in 46/68 (68%) cases with disagreement in 22/68 (32%). On 19 occasions CHD was incorrectly suspected and in three cases CHD was missed. These results indicate a fair level of agreement between the sonographer and fetal cardiologist (κ-statistic = 0.25, sensitivity = 0.70, specificity = 0.67).

In 56/68 (82%) cases the fetal tele-echocardiogram (D2) indicated a normal fetal heart with 12/68 (18%) suggesting CHD. On 97% of occasions D2 was confirmed by ‘hands-on’ FE (D3). There was one false positive and one false negative diagnosis. In one fetal tele-echocardiogram a VSD was diagnosed. On the ‘hands-on’ FE again a VSD was suspected but on closer examination the ventricular septum was judged to be intact. The false negative diagnosis was in a fetus with double outlet right ventricle. The fetus had multiple extra-cardiac abnormalities and the quality of the tele-link was noted to be poor because of maternal obesity and difficult fetal position. These results indicate an excellent level of agreement between fetal tele-echocardiography and ‘hands-on’ FE (κ-statistic = 0.89, sensitivity = 0.91, specificity = 0.98, positive predictive value = 0.91, negative predictive value = 0.98).

Radiographer's evaluation

Radiographers were highly satisfied with their involvement in the study. There was a consistent shift of responses towards increased confidence in fetal echocardiography technique and satisfaction with the telemedicine process (table 2). The mean total questionnaire score before the study was 16.8/30 compared with 24.4/30 after the study. This finding is confirmed on comparing individual radiographer's total questionnaire score (out of 30) at the start and end of the study. Using a Wilcoxon-signed ranks test there was a significant increase in questionnaire score following participation in this study (p=0.043).

Discussion

This study demonstrates that FE, performed by obstetric sonographers, facilitated by a telemedicine is technically feasible, reliable, diagnostically accurate and not particularly time consuming. This is the largest study of its kind. Sharma et al conducted a smaller, similar study. A high degree of diagnostic accuracy was also achieved. However, FEs were performed by paediatric cardiologists already proficient and a high proportion of tele-links were aborted (11%).25 We believe the present study provides a more realistic assessment of the conditions under which a fetal tele-cardiology service would operate.

Fetal cardiology is well suited to telemedicine. It is a specialty principally involving medical imaging and is highly centralised. The vast majority of fetuses with CHD are born from pregnancies without a recognisable antenatal risk factor.1 Obviously, formal evaluation by a fetal cardiologist cannot be offered to every single pregnancy.4 In order to maximise detection of CHD, greater proficiency from the non-specialist is required during the main formal evaluation of the fetus: the routine anomaly scan. This would be promoted by ongoing refreshment of skills.10 A significant positive feature of real-time fetal tele-echocardiography is the continued support provided to sonographers performing fetal anomaly scans in DGHs.7

A remote fetal cardiology service would have attendant costs which, unlike paediatric cardiology, are not offset by savings in interhospital transfers.21 The costs of delivering this service per centre comprise start-up and running costs. Start-up costs totalled £6184 (Codec and installation). The running costs are £1895 (line rental and service contract) and professional time and call costs (6 × standard phone call). However, the possible establishment of a ‘one-stop-shop’ for ‘high-risk’ pregnancies in which the routine fetal anomaly scan is followed, on the same day, by a remote FE could potentially reduce costs, relieve pressure on the regional service and present time and cost savings to the patient.

The relatively small study size and numbers with pathology (typical of this cohort) have reduced the power of the study and resulted in relatively wide CIs. The late gestational age at which the fetal tele-echocardiograms were performed could diminish their effectiveness by reducing the scope for intervention and termination.26 However, there is little reason to believe that fetal tele-echocardiography would not be as successful if performed between 18 and 20 weeks of gestation.27 28 Audio-visual contact with the parents is an undoubted advantage of real-time telemedicine. However, it is our experience that when CHD has been identified by fetal tele-echocardiography, parental counselling is more difficult. For example, conveying empathy across a tele-link to upset parents is difficult.

Conclusions

CHD may be reliably diagnosed and excluded by real-time telemedicine. It is highly acceptable to service users. Ultimately the aim of future work should be aimed towards the establishment of a regional fetal tele-echocardiography service that supports DGHs, improves access to fetal cardiology, reduces pressure on the regional services and reduces patient travelling and attendant costs.

Acknowledgments

The authors would like to thank the obstetric sonographers and consultant obstetricians from Altnagelvin Area Hospital for their participation in this study. The authors would also like to acknowledge the advice provided by Sam McMaster of Questmark.

References

Footnotes

  • Competing interests None.

  • Funding Research was provided by the Royal Belfast Hospital for Sick Children.

  • Ethics approval This study was conducted with the approval of the COREC – Peterborough committee.

  • Provenance and peer review Not commissioned; externally peer reviewed.

Linked Articles