Abstract
Objective: To investigate the relation between the measured intravascular blood volume (BV) and current methods of indirectly assessing BV status in sick preterm infants on the first day of life.
Methods: Thirty eight preterm infants of gestation 24–32 weeks (median 30) and weight 480–2060 g (median 1220) were studied. Red cell volume was measured by the fetal haemoglobin dilution method in six infants and by the biotin labelled autologous red cell dilution method in the remaining 32. Total BV was calculated by dividing red cell volume by packed cell volume. Indirect assessments of BV status using heart rate (HR), core-peripheral temperature difference, mean arterial pressure, base excess, and packed cell volume were recorded.
Results: The mean (SD) initial measured BV was 71 (12) ml/kg (range 53–105). The mean HR was 148 beats/min (range 130–180), which correlated positively (r = 0.39, p = 0.02) with BV (higher HR was associated with higher BV). The mean base excess was −3.19 mmol/l (range −18 to +6.2). The negative base excess correlated significantly positively (r = 0.41, p < 0.01) with BV (more acidotic babies tended to have higher BV). There was no significant correlation between core-peripheral temperature difference, mean arterial pressure, or packed cell volume and BV. Regression analysis showed that base excess and HR were significantly related to BV; base excess alone can predict variability in BV only to17%, and base excess with HR can predict variability in BV to 29%.
Conclusion: The conventional clinical and laboratory indices are poor predictors of measured blood volume.
- BV, blood volume
- c-pT, core-peripheral temperature difference
- HR, heart rate
- MAP, mean arterial pressure
- PCV, packed cell volume
- RCV, red cell volume
- blood volume
- heart rate
- core-peripheral temperature difference
- mean arterial pressure
- base deficit
Statistics from Altmetric.com
- BV, blood volume
- c-pT, core-peripheral temperature difference
- HR, heart rate
- MAP, mean arterial pressure
- PCV, packed cell volume
- RCV, red cell volume
The clinical question often arises “does the sick preterm infant need volume expansion or fluid restriction?” It has been suggested that it would be easier to sort out which intravenous fluid to use for volume expansion than to decide to whom it should be given and when.1 There is widespread clinical acceptance of the rather simplistic concept that hypovolaemia can be suspected from a combination of hypotension, tachycardia, falling packed cell volume (PCV), and metabolic acidosis. However, Ebert et al2 have shown that, in healthy adult volunteers, clinical symptoms or signs of hypovolaemia are not seen despite the loss of up to 15–20% of total blood volume (BV), even on rapid removal of the blood within 6–13 minutes. Shippy et al3 have reported that, in critically ill adults, the commonly monitored variables such as mean arterial pressure (MAP), central venous pressure, pulmonary artery wedge pressure, heart rate (HR), PCV, and cardiac output are not of themselves reliable reflections of intravascular volume status.
Haematological variables involved in oxygen delivery4,5 include haemoglobin concentration or PCV, red cell volume (RCV), and BV. In sick infants with impairment of capillary integrity, RCV and plasma volume tend to fall and fluctuate because of extravasation of components of the plasma, so BV cannot be predicted accurately from PCV/haemoglobin concentration.6 In preterm infants, BV strongly influences the development of postnatal lung function7 and outcome.8–10
The aim of this study was to find out whether the current methods of indirect assessment of BV status in sick preterm infants correspond with the directly measured intravascular volume.
PATIENTS AND METHODS
Thirty eight babies born in The Queen Mother’s Hospital, Glasgow were included in the study. The median gestational age of the study population was 30 weeks (range 24–32), and median birth weight was 1220 g (range 480–2060). The mode of delivery was caesarean section in 19 infants (11 male) and vaginal in 19 infants (9 female). Antepartum haemorrhage had occurred in 10 cases. The time of clamping of the umbilical cord was variable (10–90 seconds). Twenty infants were ventilated (median oxygen 50% (21–95%)), six were receiving nasal continuous positive airway pressure (median oxygen 21% (21–40%)), and the rest were stable in air or low flow oxygen. One infant was receiving dopamine, four received plasma protein solution (for poor perfusion), and five received fresh frozen plasma (in three cases for poor perfusion and in two cases for deranged coagulation) within four hours of birth. None of the infants had received blood transfusion or colloid infusion before BV measurement and collection of the clinical and laboratory indices. Thirty five infants had blood cultures performed soon after birth but all proved negative. The study was approved by the hospital ethics committee; informed written parental consent was obtained.
Measurement of BV
RCV was measured using the fetal haemoglobin dilution method11 in six babies receiving blood transfusion, and by the biotin labelled autologous red cell dilution12 method in the remaining 32 babies. RCV was measured within six hours of birth in 33 infants and within 24 hours in the rest. Total BV was calculated by dividing RCV by PCV determined using a venous or arterial sample within four hours of birth.
The highest documented core-peripheral temperature differences (c-pT), HR, and base excess and the lowest recorded intra-arterial MAP during the first six hours were used. The base excess was estimated on arterial, capillary, and venous blood in 21, 14, and 3 infants respectively.
Statistical analysis
The dependence between each of the potential explanatory variables (HR, c-pT, MAP, base excess, and PCV) and BV was measured by Pearson’s sample correlation coefficient and assessed for significance by the corresponding t test of zero correlation. Stepwise multiple regression using both forward and backward variable selection techniques was used to identify which, if any, of these potential explanatory variables could be used collectively to predict BV.
RESULTS
The mean (SD) initial BV was 71 (12) ml/kg (range 53–105). Mean HR was 148 beats/min (range 130–180). HR correlated positively with BV; higher HR was associated with higher BV (table 1, fig 1A). The mean base excess was −3.19 mmol/l (range −18 to +6.2). The negative base excess correlated significantly positively (r = 0.41, p < 0.01) with BV (fig 1D, table 1); more acidotic babies tended to have higher BV. The c-pT ranged from 0.5 to 3°C (mean (SD) 1.28 (0.7)). Intra-arterial MAP ranged from 27 to 50 mmHg (mean 39). The PCV at birth ranged from 0.4 to 0.68 (mean 0.5). There was no significant correlation between c-pT, MAP, or PCV and BV (table 1, figs 1B,C,E).
Summary statistics and correlations with blood volume of potential explanatory variables
Plots of blood volume against each of the potential explanatory variables. c-pT, Core-peripheral temperature difference; MAP, mean arterial pressure; PCV, packed cell volume.
Stepwise multiple regression analysis showed that the base excess and HR were significantly related to BV. The base excess on its own explains 17% of the variability in BV, and this was only increased to 29% when HR and base excess were used together. On further analyses excluding two observations with large BV, even the HR (r = 0.10, p = 0.56) and base excess (r = 21, p = 0.23) lose the significant correlation with BV.
DISCUSSION
Commonly monitored variables such as MAP, HR, base excess, and PCV are necessary for the management of sick preterm infants. The data from this study show that they do not predict measured BV at all well. PCV, which represents a ratio of red cells to plasma in the blood, correlates with RCV in healthy subjects. However, not only after acute blood loss, but also in many sick patients with impairment of capillary integrity, plasma volume fluctuates and falls because of extravasation of plasma components, and so BV cannot be accurately predicted from PCV.5,12
The mean BV of the preterm infants in this study was low, 71 ml/kg (predicted normal > 90 ml/kg).5,13 Published data on BV of preterm infants of 24–32 weeks gestation are negligible. Mollison et al14 reported that the average BV was 84.7 ml/kg (range 68.5–100.3) using a 51Cr labelled red cell method in full term healthy babies within 24 hours of birth. Nelle et al15 comparing BV in full term babies whose umbilical cords were clamped either early or after a delay found mean (SD) values of 70 (9) ml/kg (early) and 90 (8) ml/kg (delayed). This was based on measured placental residual BV deducted from an assumed total fetoplacental BV of 115 ml/kg. Leipala et al16 studied preterm infants born at 26–31 weeks gestation who needed blood transfusions, and reported that BV was 70 (9) ml/kg in appropriately grown babies (n = 6) and 70 (16) ml/kg in babies who were small for gestational age (n = 17).
Hypovolaemia may cause tachycardia and metabolic acidosis in children and adults. However, we found no clinically helpful correlation between BV and HR or base excess. Leipala et al16 also found no correlation between HR and BV in preterm infants who had been judged to need blood transfusion. Theye and Tuohy17 reported that there was no correlation between BV and HR in adult patients undergoing major surgery. It is interesting to note that none of the babies in this study with low BV had negative base excess > 8, but two babies with normal BV had a negative base excess of > 10. Most did not have negative base excess values that would cause clinical concern in spite of having low BV. There are no comparative published data correlating BV and base excess.
There was no correlation between BV and c-pT in this study. Lambert et al18 reported moderate correlation between plasma arginine vasopressin concentration and c-pT, but no correlation between plasma arginine vasopressin and blood pressure before and after volume expansion in preterm infants. Our findings are similar to other reports in which there was no correlation between c-pT and haemodynamic variables such as cardiac index, central venous pressure, systemic vascular resistance index, stroke volume index, or lactate concentration in children and adults undergoing intensive care.19–22 It has been suggested that management of shock using temperature gradient as a measure of the patient’s haemodynamic status is irrational and may be unsafe.19,21
PCV did not predict BV well in this study. Babies with PCV of 0.41 had BV ranging from 50 to 105 ml/kg (fig 1E), and this accords with findings in previous reports.8,11,12 There was no correlation between BV and blood pressure in this study, but Linderkamp et al23 found a weak correlation between BV and blood pressure in a combined group of preterm and term infants. However, it is well documented that clinical hypotension appears only when there has been substantial volume loss.2,24
Measuring BV by the fetal haemoglobin dilution method11,12 and the biotin labelled autologous red cell dilution method25–27 has been well validated. However, studies of reproducibility and repeatability of these methods of BV measurement in human subjects have not been described because of ethical and practical constraints. Many validated BV methods have been reported in physiological studies of the circulation, despite this inevitable limitation.14,16,28,29 The methods reported here are technically complex and time consuming, hence not practical for routine clinical use. Measurement of BV by the fetal haemoglobin dilution technique is applicable when a baby receives a blood transfusion, but cannot be used after one or two transfusions as autologous fetal haemoglobin is replaced.
Thirty three infants had BV measured during the six hour period of surrogate clinical monitoring data collection. In infants whose BV was determined between six and 24 hours after birth, the measured BV may not represent the exact circulating BV at the time that the rest of the data were collected—that is, during the first six hours. However, there was no clinical evidence of oedema, suggesting no significant capillary leak, and insensible water loss would have been minimised by nursing in closed humidified incubators. The recorded BV for these babies is the sum of the measured BV and the volume of sampling blood loss from birth until the time of BV measurement.
It could be argued that values of about 70 ml/kg may be sufficient for this study population, thus explaining the lack of clear impact of measured “low” BV on the commonly monitored variables used for assessment of intravascular volume status. However, recalling that, in healthy subjects, BV expressed per kg lean body mass is 100 ml, one must question seriously the adequacy of such a striking discrepancy in these relatively hypovolaemic critically ill infants. The question remains do such BV values represent a threat to the sick preterm infant’s circulation, tissue perfusion, and outlook?
CONCLUSION
Our ability to assess BV using conventional clinical and laboratory evaluation is poor.