Article Text
Abstract
AIMS To test whether cardiac output acts as a compensatory response to changes in haematocrit.
METHODS A cohort of 38 preterm infants (27–31 weeks' gestation) was studied with repeated Doppler measurements of left ventricular output during the 1st month of life. Red blood cell transport was calculated when the duct was closed.
RESULTS Multiple regression analysis showed that left ventricular output correlated negatively with haematocrit when the duct was closed (n = 84) and when it was open (n = 59). The influence of an increase of 10% in haematocrit absolute value on mean (SD) left ventricular output was estimated at −55 (11) ml/kg/min. Mean (SD) red blood cell transport was 132 (30) ml/kg/min with a mean (SD) intra-individual variability of 20% (8.8%). Red blood cell transport was increased more frequently by left ventricular output than by haematocrit. Haematocrit and left ventricular output but not red blood cell transport were dependent on postnatal age.
CONCLUSION These results suggest that in preterm infants cardiac output adaptation is effective in attenuating the effects of red blood cell mass variations on systemic oxygen carrying capacity.
Key messages
Key messages
Red cell transport is an estimation of oxygen carrying capacity
The effects of red blood cell mass variations on oxygen carrying capacity depend on the compensatory response provided by cardiac output adaptation
- prematurity
- haematocrit
- cardiac output
- polycythaemia