Randomised trial of volume controlled versus time cycled, pressure limited ventilation in preterm infants with respiratory distress syndrome

Abstract

Fifty preterm infants weighing 1200 g or more with clinical and radiographic evidence of respiratory distress syndrome, requiring both mechanical ventilation and exogenous surfactant replacement, were randomly allocated to receive either volume controlled ventilation or time cycled, pressure limited ventilation. Tidal volume delivery in each group was deliberately controlled at 5–8 ml/kg so that the only difference between the two groups was the ventilatory modality, the manner in which tidal volume was delivered. The rest of the ventilatory management and clinical care was done according to protocol. The two modes of ventilation were compared by determining the time required to achieve pre-determined success criteria, based on either the alveolar–arterial oxygen gradient or the mean airway pressure as a standard against which the speed of weaning could be objectively assessed. Infants randomised to volume controlled ventilation met success criteria sooner and had a shorter duration of mechanical ventilation. These babies also had a significantly lower incidence of intraventricular haemorrhages and abnormal periventricular echodensities on ultrasound scans.

 Volume controlled ventilation seems to be both safe and effective in this group of patients.

  • assisted ventilation
  • alveolar–arterial oxygen gradient
  • mean airway pressure
  • respiratory distress syndrome

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes