Diagnosis of patent ductus arteriosus

https://doi.org/10.1053/siny.2000.0037Get rights and content

Abstract

This review shows that clinical signs cannot be relied on to reveal left-to-right ductal shunting in the preterm. Echocardiography can define many of the haemodynamic features, including occult ventricular dysfunction, and categorize shunts into small, moderate or large, without defining ‘significance’ which is multifactorial. Large shunts have an elevated left atrial:aortic root ratio (>1.3:1 or >1.5:1, depending on fluid and diuretic policy) a ductal diameter >1.4 mm and retrograde diastolic flow in the descending aorta exceeding 30% of the antegrade flow. The neonatal clinician and echocardiographer is reminded to remain wary of occult congenital heart disease, particularly before closing the ductus.

References (45)

  • F Walther et al.

    Pulsed Doppler measurement of left ventricular output as early predictor of symptomatic patent ductus arteriosus in very preterm infants

    Biology of the Neonate

    (1989)
  • JR Skinner et al.

    Pulmonary and systemic arterial pressure in hyaline membrane disease

    Arch Dis Child

    (1992)
  • N Evans et al.

    Early ductal shunting and intraventricular haemorrhage in ventilated preterm infants

    Arch Dis Child

    (1996)
  • GP Heldt et al.

    Closure of the ductus arteriosus and mechanics of breathing in preterm infants after surfactant therapy

    Pediatr Res

    (1989)
  • LNJ Archer et al.

    The silent ductus arteriosus in idiopathic respiratory distress syndrome

    Acta Paediatr Scand

    (1984)
  • LM Valdez-Cruz et al.

    Specificity and accuracy of echocardiographic diagnosis and clinical criteria for diagnosis of patent ductus arteriosus in fluid-restricted infants

    J Pediatr

    (1981)
  • C Kupfershmid et al.

    Sensitivity, specificity and predictive value of clinical findings, m-mode echocardiography and continuous-wave Doppler sonography in the diagnosis of symptomatic patent ductus arteriosus in preterm infants

    Eur J Pediatr

    (1988)
  • H Hirsimaki et al.

    Doppler ultrasound and clinical evaluation in detection and grading of patent ductus arteriosus in neonates

    Cr Care Med

    (1990)
  • DA Roberson et al.

    Color Doppler flow mapping of the patent ductus in very low birth weight neonates: echocardiographic and clinical findings

    Pediatr Cardiol

    (1994)
  • N Evans et al.

    Longitudinal changes in the diameter of the ductus arteriosus in ventilated preterm infants: correlation with respiratory outcomes

    Arch Dis Child

    (1995)
  • M Mellander et al.

    Prediction of symptomatic patent ductus arteriosus in preterm infants using Doppler and m-mode echocardiography

    Acta Paediatr Scand

    (1987)
  • JR Skinner et al.

    Cardiorespiratory collapse and the silent ductus

    Klinische Padiatrie

    (1991)
  • Cited by (0)

    f1

    Correspondence to: Dr Jon Skinner MD, MRCP (UK), DCH, FRCPCH, Paediatric Cardiologist, Green Lane Hospital, Green Lane West, Auckland, New Zealand. Tel.: +64 9 6389909; Fax +64 9 631 0785; E-mail:[email protected]

    View full text