Regular ArticleDiagnosis of patent ductus arteriosus
References (45)
- et al.
Duration of ductal shunting in healthy preterm infants: An echocardiographic color flow Doppler study
J Pediatr
(1988) - et al.
The silent ductus arteriosus
J Pediatr
(1978) - et al.
Early echocardiographic prediction of symptomatic patent ductus arteriosus in preterm infants undergoing mechanical ventilation
J Pediatr
(1995) - et al.
Hemodynamic prediction of complications in neonatal respiratory distress syndrome
J Pediatr
(1995) - et al.
Effects of left-to-right ductus shunting on left ventricular output and cerebral blood flow velocity in 3 day old preterm infants with and without severe lung disease
J Pediatr
(1988) - et al.
Effect of patent ductus arteriosus on left ventricular output in premature infants
J Pediatr
(1983) - et al.
Combined noninvasive assessment of the ductus arteriosus in the preterm infant before and after Indomethacin treatment
American Journal of Cardiology
(1984) - et al.
Assessment of ductus arteriosus shunt in preterm infants supported by mechanical ventilation: effects of interatrial shunting
J Pediatr
(1994) - et al.
Continuous wave Doppler ultrasonographic quantitation of patent ductus arteriosus flow
J Pediatr
(1982) - et al.
Non-invasive determination of pulmonary arterial pressure in healthy neonates
Arch Dis Child
(1991)
Pulsed Doppler measurement of left ventricular output as early predictor of symptomatic patent ductus arteriosus in very preterm infants
Biology of the Neonate
(1989)
Pulmonary and systemic arterial pressure in hyaline membrane disease
Arch Dis Child
(1992)
Early ductal shunting and intraventricular haemorrhage in ventilated preterm infants
Arch Dis Child
(1996)
Closure of the ductus arteriosus and mechanics of breathing in preterm infants after surfactant therapy
Pediatr Res
(1989)
The silent ductus arteriosus in idiopathic respiratory distress syndrome
Acta Paediatr Scand
(1984)
Specificity and accuracy of echocardiographic diagnosis and clinical criteria for diagnosis of patent ductus arteriosus in fluid-restricted infants
J Pediatr
(1981)
Sensitivity, specificity and predictive value of clinical findings, m-mode echocardiography and continuous-wave Doppler sonography in the diagnosis of symptomatic patent ductus arteriosus in preterm infants
Eur J Pediatr
(1988)
Doppler ultrasound and clinical evaluation in detection and grading of patent ductus arteriosus in neonates
Cr Care Med
(1990)
Color Doppler flow mapping of the patent ductus in very low birth weight neonates: echocardiographic and clinical findings
Pediatr Cardiol
(1994)
Longitudinal changes in the diameter of the ductus arteriosus in ventilated preterm infants: correlation with respiratory outcomes
Arch Dis Child
(1995)
Prediction of symptomatic patent ductus arteriosus in preterm infants using Doppler and m-mode echocardiography
Acta Paediatr Scand
(1987)
Cardiorespiratory collapse and the silent ductus
Klinische Padiatrie
(1991)
Cited by (0)
- f1
Correspondence to: Dr Jon Skinner MD, MRCP (UK), DCH, FRCPCH, Paediatric Cardiologist, Green Lane Hospital, Green Lane West, Auckland, New Zealand. Tel.: +64 9 6389909; Fax +64 9 631 0785; E-mail:[email protected]
Copyright © 2001 Harcourt Publishers Ltd. All rights reserved.