Measurement of blood flow by ultrasound: Accuracy and sources of error

https://doi.org/10.1016/0301-5629(85)90035-3Get rights and content

Abstract

Doppler ultrasound has now developed to the point where the rate of flow of blood in a given vessel can be measured with appropriate instrumentation. The theoretical basis of Doppler flow measurement is reviewed in this paper, with particular emphasis on the potential and actual sources of error. Three distinct approaches are identified, and the strengths and weaknesses of each discussed. The separate errors involved in estimating the vessel cross-sectional area, the angle of approach, and the Doppler shift are analyzed, together with the question of the uniformity of scattering from the blood. In vivo and in vitro tests of the accuracy obtained using a number of Doppler flow measuring instruments are then reviewed. It is concluded that the Doppler methods are capable of good absolute accuracy when suitably designed equipment is used in appropriate situations, with systematic errors of 6% of less. There are, however, considerable random errors, attributable primarily to errors in measuring the cross-sectional area and the angle of approach. Repeating the measurement of flow several times and averaging the results can reduce these random errors to an acceptable level.

References (63)

  • R.S. Mackay

    Non-invasive cardiac output measurement

    Microvasc. Res.

    (1972)
  • V.L. Newhouse et al.

    On increasing the range of pulsed Doppler systems for blood flow measurement

    Ultrasound in Med. & Biol.

    (1980)
  • R.S. Reneman et al.

    Local Doppler audio spectra in normal and stenosed carotid arteries in man

    Ultrasound in Med. & Biol.

    (1979)
  • J.P. Woodcock

    Development of the ultrasonic flowmeter

    Ultrasound in Med. & Biol.

    (1975)
  • B.A.J. Angelsen et al.

    Transcutaneous measurement of blood flow velocity in the human aorta

    Cardiovase. Res.

    (1976)
  • B.A.J. Angelsen

    A theoretical study of the scattering of ultrasound from blood

    IEEE Trans. Biomed. Engng BME-27

    (1980)
  • B.A.J. Angelsen et al.

    Discrete time estimation of the mean Doppler frequency in ultrasonic blood velocity measurements

    IEEE Trans. Biomed. Engng. BME-30

    (1983)
  • M.G.J. Arts et al.

    On the instantaneous measurement of blood flow by ultrasonic means

    Med. Biol. Engng

    (1972)
  • P.S. Avasthi et al.

    A comparison of echo-Doppler and electromagnetic renal blood flow measurements

    J. Ultrasound Med.

    (1984)
  • D.W. Baker

    Pulsed ultrasonic Doppler blood flow sensing

    IEEE Trans. Sonics & Ultrasonics SU-17

    (1970)
  • D.W. Baker et al.

    Pulsed Doppler techniques: some examples from the University of Washington

    Ultrasound Med. Biol.

    (1976)
  • D.W. Baker et al.

    Doppler principles and techniques

  • W.R. Brody et al.

    Theoretical analysis of the cw Doppler ultrasonic flowmeter

    IEEE Trans. Biomed. Engng BME-21

    (1974)
  • C.R. Burkhardt

    Comparison between spectrum and time interval histogram of ultrasound Doppler signals

    Ultrasound in Med. & Biol.

    (1981)
  • D. Cathignol et al.

    Transcutaneous blood flow measurements using pseudo random noise Doppler system

    IEEE Trans. Biomed. Engng BME-27

    (1980)
  • P.A. Doriot et al.

    Quantitative analysis of flow conditions in simulated vessels and large human arteries and veins by means of ultrasound

  • S.H. Eik-Nes et al.

    Measurement of human fetal blood flow

    Brit. Med. J.

    (1980)
  • S.H. Eik-Nes et al.

    Transcutaneous measurement of human fetal blood flow

  • P.J. Fish

    A method of transcutaneous blood flow measurement—accuracy considerations

  • D.C. Fisher et al.

    The mitral valve orifice method for noninvasive two-dimensional echo Doppler determinations of cardiac output

    Circulation

    (1983)
  • H. Furuhata et al.

    An ultrasonic blood flow measuring system to detect the absolute volume flow

    Jpn J. Med. Electron. Biol. Engng

    (1978)
  • Cited by (0)

    View full text