Effect of distension on release of surfactant es excised dogs' lungs,☆☆

https://doi.org/10.1016/0034-5687(76)90021-9Get rights and content

Abstract

The freshly excised lower lobes of lungs of dogs were washed by filling and emptying the lobe with isotonic saline. The wash fluid was then discarded and the procedure was repeated 9 times. The 9th wash was collected and used for measurements of surface tension and lecithin content. The lobe was then constantly inflated for 3 hr; washed again with isotonic saline (10th wash) and surface tension and lecithin content of wash fluid measured. When the lobe was inflated with air, at room temperature, the surface activity and the lecithin content of the 10th wash were increased in comparison to the 9th wash. This increase was not noted when the lobe was inflated with 100% N2 or 100% O2 at room temperature, or with air at 6° C. Increase in the surface activity of the 1 Oth wash was directly related to the inflating pressures used. This study suggests that distension of the lung enhances the release of surfactant and that this release is a metabolically active process. It appears also that 100% O2, has an inhibitory effect on this process.

References (20)

There are more references available in the full text version of this article.

Cited by (68)

  • Principles of lung-protective ventilation

    2022, Goldsmith's Assisted Ventilation of the Neonate: An Evidence-Based Approach to Newborn Respiratory Care, Seventh Edition
  • Principles of Lung-Protective Ventilation

    2017, Assisted Ventilation of the Neonate: An Evidence-Based Approach to Newborn Respiratory Care: Sixth Edition
  • Reducing Lung Injury during Neonatal Resuscitation of Preterm Infants

    2008, Journal of Pediatrics
    Citation Excerpt :

    The very preterm infant has difficulty maintaining FRC and upper airway patency for many reasons.42 CPAP or PEEP can reduce the risk of atelectrauma and improve respiratory function in various ways: (1) CPAP reduces upper airway obstruction by decreasing upper airway resistance and increasing the pharyngeal cross-sectional area;43 (2) both CPAP and PEEP increase FRC;44,45 (3) CPAP and PEEP reduce inspiratory resistance44,46 by dilating the airways and allow a larger VT for a given pressure with reduced work of breathing;47 (4) CPAP and PEEP increase the compliance and VT of stiff lungs with a low FRC by stabilizing the chest wall;47 (5) CPAP and PEEP increase the mean airway pressure and improve ventilation–perfusion mismatch;48 (6) PEEP conserves surfactant on the alveolar surface;49,50 and (7) as CPAP and PEEP increase lung volume, oxygenation also improves.19,20 Studies using animal models of resuscitation support the use of PEEP in the DR.51-53 Polglase et al54 reported that PEEP of 4 to 8 cm H2O maintained arterial oxygenation and decreased pulmonary vascular blood flow with no adverse effects to the cardiovascular system.

  • Neonatal Mechanical Ventilation

    2008, Mechanical Ventilation: Clinical Applications and Pathophysiology
  • The respiratory system in spinal cord injury

    2000, Physical Medicine and Rehabilitation Clinics of North America
View all citing articles on Scopus

Preliminary reports of this study have been presented at the meeting of the American Physiological Society: Fed. Proc. (1973) 32: 401.

☆☆

This study was supported by the Medical Research Council of Canada.

View full text