Continuous neonatal evaluation in the delivery room by pulse oximetry

  • Original Articles
  • Published:
Journal of Clinical Monitoring Aims and scope Submit manuscript

Abstract

The pulse oximeter, a noninvasive and continuous monitor of arterial oxygenation that is reliable in adults, children, and infants, was evaluated for use in neonates in the delivery suite. One hundred newborn infants, weighing 850 to 5,230 g each, delivered vaginally or by cesarean section with general or epidural anesthesia were studied. After delivery, each infant was placed in a radiant warmer, and a pulse oximetry probe was placed on the right hand. Hemoglobin saturation was then recorded for 15 minutes. Initial pulse oximetry values were obtained in less than one minute after cord clamping in 43% of infants, less than two minutes in 81 %, and less than three minutes in 98%. Average arterial oxygen saturation was 59% at 1 minute (43 infants), 68% at 2 minutes (81), 82% at 5 minutes (98), and 90% at 15 minutes (91). Oxygen saturation was less than 30% in 12 neonates and less than 50% in 26 neonates at some time during the 15-minute monitoring period. Oxygen saturation did not differ significantly between neonates delivered vaginally or by cesarean section, regardless of the presence or type of anesthetic used. Arterial oxygen saturation measured by pulse oximetry showed a statistically significant relationship when compared with the traditional Apgar scoring system. Pulse oximetry was found to be very useful in objectively judging the adequacy of resuscitative efforts, as well as in identifying children who had marked arterial desaturation during the early neonatal period.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Yelderman M, New W, Jr. Evaluation of pulse oximetry. Anesthesiology 1983; 59:349–352

    Article  PubMed  CAS  Google Scholar 

  2. Modanlou H, Yeh SY, Hon EH, Forsythe A. Fetal and neonatal biochemistry and Apgar scores. Am J Obstet Gynecol 1973; 117:942–951

    PubMed  CAS  Google Scholar 

  3. Huch R, Huch A. Maternal and fetal acid-base balance and blood gas measurements. In: Beard RW, Nathanielsz PW, eds. Fetal physiology and medicine. New York: Marcel Dekker, 1984:713–756

    Google Scholar 

  4. Baxi LV. Current status of fetal oxygen monitoring. Clin Perinatol 1982; 9:423–431

    PubMed  CAS  Google Scholar 

  5. Swanstrom S, Bratteby LE. Metabolic effects of obstetric regional analgesia and of asphyxia in the newborn infant during the first two hours after birth. Acta Paediatr Scand 1981; 70:811–818

    Article  PubMed  CAS  Google Scholar 

  6. Oliver TK, Jr, Demis JA, Bates GD. Serial blood gas tensions and acid-base balance during the first hour of life in human infants. Acta Paediatr 1961; 50:346–360

    Article  PubMed  CAS  Google Scholar 

  7. Koch G, Wendel H. Adjustment of arterial blood gases and acid base balance in the normal newborn infant during the first week of life. Biol Neonat 1968; 12:136–161

    PubMed  CAS  Google Scholar 

  8. Mihm FG, Halperin BD. Noninvasive detection of profound arterial desaturations using a pulse oximetry device. Anesthesiology 1985; 62:85–87

    Article  PubMed  CAS  Google Scholar 

  9. Fanconi S, Doherty P, Edmonds JF, et al. Pulse oximetry in pediatric intensive care: comparison with measured saturations and transcutaneous oxygen tension. J Pediatr 1985; 107:362–366

    Article  PubMed  CAS  Google Scholar 

  10. Krauss AN, Waldman S, Frayer WW, Auld PAM. Noninvasive estimation of arterial oxygenation in newborn infants. J Pediatr 1978; 93:275–278

    Article  PubMed  CAS  Google Scholar 

  11. Monaco F, Feaster WW, McQuitty JC, Nickerson BG. Continuous noninvasive oxygen saturation monitoring in sick newborns. Respir Care 1983; 28:1362

    Google Scholar 

  12. Deckardt R, Steward DJ. Noninvasive arterial hemoglobin oxygen saturation versus transcutaneous oxygen tension monitoring in the preterm infant. Crit Care Med 1984; 12:935–939

    Article  PubMed  CAS  Google Scholar 

  13. Apgar V. A proposal for a new method of evaluation of the newborn infant. Curr Res Anesth Analg 1953: 32:260–267

    PubMed  CAS  Google Scholar 

  14. Brooks TD, Paulus DA, Winkle WE. Infrared heat lamps interfere with pulse oximeters. Anesthesiology 1984; 61:630

    Article  PubMed  CAS  Google Scholar 

  15. Walsh LA, Clarke TA: Stabilization of the newborn. In: Ziai M, Clarke TA, Merritt TA, eds. Assessment of the newborn. Boston: Little, Brown, 1984:20–31

    Google Scholar 

  16. Welch KA, Philips JB III. Management of the depressed newborn. Clin Obstet Gynecol 1984; 27:125–133

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

House, J., Schultetus, R.R. & Gravenstein, N. Continuous neonatal evaluation in the delivery room by pulse oximetry. J Clin Monitor Comput 3, 96–100 (1987). https://doi.org/10.1007/BF00858357

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00858357

Key words

Navigation