Table 3

Deposition of surfactant in airway and ventilator circuit (as % of amount nebulised): mean (SEM)

GroupTrachea and carinaInspiratory circuit3-150
Exosurf
A1 (jet)0.20 (0.08)12.79 (3.20)
A2 (ultrasonic)1.97 (0.48) 9.83 (1.81)
B1 (jet)0.13 (0.01)11.21 (1.96)
B2 (ultrasonic)1.57 (0.46) 7.25 (0.47)
p (ANOVA)0.004 0.407
Student-Newman-Keul test (p < 0.05)A2 and B2>A1 and B1
  • 3-150 Inspiratory tubing+endotracheal tube+endotracheal tube connector+Y-connector.