Register for email alerts and news feeds:
This journal | BMJ Group
rss
The most recent version of this article was published on 1 November 2009

Arch. Dis. Child. Fetal Neonatal Ed.. Published Online First: 1 July 2009. doi:10.1136/adc.2009.162446
Copyright © 2009 BMJ Publishing Group Ltd & Royal College of Paediatrics and Child Health.

Original articles

Flow-cycled versus time-cycled sIPPV in preterm babies with RDS: a breath to breath randomised cross-over trial

Daniele De Luca 1*, Giorgio Conti 2, Marco Piastra 2 and Piermichele Paolillo 1

1 Casilino General Hospital, Italy
2 Catholic University of the Sacred Heart, Italy

* To whom correspondence should be addressed. E-mail: dm.deluca{at}fastwebnet.it.

Accepted 23 June 2009


Abstract

Objectives: Few data exist about patient triggered ventilation techniques in neonatal critical care. Our aim was to compare pressure limited sIPPV in the classical time cycled (TC-sIPPV) mode against flow cycled (FC-sIPPV) modality. In this latter, typical sIPPV full respiratory support is provided but both the initiation and the end of inflation are determined by the infant’s spontaneous respiratory efforts by using airway flow changes.

Setting: A 3rd level neonatal intensive care unit. Patients and intervention. Ten preterm babies (< 32 wks gestation) were randomised to receive 1h FC-sIPPV followed by 1h TC-sIPPV or the inverse shift, according to a computer created randomization table. Eligible babies had hyaline membrane disease and received 200 mg/kg surfactant at least 6 hours before the study period. Respiratory mechanics, ventilatory and vital parameter data were registered real time.

Results: FC-sIPPV resulted in lower rate-volume ratio, pressure x rate product, mean airway pressure and heart rate; tidal volume and oxygen saturation were higher (all p<0.0001). Spontaneous inspiratory time was lower than usually set by the physician and it was directly correlated to birth weight (rho = 0.5, p=0.001) and gestational age (rho = 0.32, p=0.001). No differences were noticed in the mechanics and blood gas and vital parameters during the two study phases.

Conclusions: FC-sIPPV may safely result in a better patient ventilator synchrony. Inspiratory time usually set in neonatal critical care is higher than the one decided by the baby during spontaneous effort. This should be considered when establishing time cycled ventilation.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This Article

Services
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Latest from ADC

 

ADC is co-owned by the RCPCH and is the official journal of the European Academy of Paediatrics

BMJ Careers - Latest Paediatrics and Paediatric Surgery Jobs

Paediatrics and Paediatric Surgery Jobs