Arch. Dis. Child

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

Archives of Disease in Childhood - Fetal and Neonatal Edition 2006;91:F31-F35; doi:10.1136/adc.2004.058172
Copyright © 2006 BMJ Publishing Group Ltd & Royal College of Paediatrics and Child Health

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in ADC Online
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sinha, A K
Right arrow Articles by Kempley, S T
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sinha, A K
Right arrow Articles by Kempley, S T

ORIGINAL ARTICLE

Blood flow in the common carotid artery in term and preterm infants: reproducibility and relation to cardiac output

A K Sinha, C Cane, S T Kempley

Neonatal Unit, Royal London Hospital, Whitechapel, London and Department of Child Health, Barts and the London School of Medicine and Dentistry, London, UK

Correspondence to:
Correspondence to:
Dr Sinha
Neonatal Unit, Garden House, Royal London Hospital, Whitechapel, London E1 1BB, UK; a.k.sinha{at}qmul.ac.uk

Aim: To assess the reproducibility of, and determine normative data for, flow volume measurements from the right common carotid artery (CCA) and its relation to left ventricular output (LVO) in stable term and preterm babies using Doppler ultrasound.

Methods: Right CCA flow volume was measured using a near focus, high frequency transducer by obtaining intensity weighted mean velocity and right CCA diameter. LVO was determined using standard Doppler techniques. Reproducibility studies were performed on 30 newborn infants by two observers. Normative data were obtained from 40 spontaneously breathing preterm babies and 21 term babies.

Results: The intraobserver coefficient of variation for CCA flow measurements was 10.5% for observer 1 and 15.4% for observer 2, whereas the interobserver coefficient of variation was 16.4%. In term and preterm infants, right CCA flow was about 20 ml/kg/min, accounting for 11% of cardiac output. Among the preterm infants, there was a positive correlation of right CCA flow with gestation (r = 0.61, p<0.001), weight (r = 0.64, p<0.001), and LVO (r = 0.59, p<0.001). Right CCA diameter also increased with weight (r = 0.63, p<0.001) and gestation (r = 0.58, p<0.001). The proportion of LVO distributed to the right CCA did not increase with gestation, nor did the right CCA flow per kg body weight.

Conclusions: It is possible to perform reproducible measurements of flow volume in the CCA of newborn infants. In stable, spontaneously breathing babies, both cardiac output and carotid flow increased with gestation and body weight. The proportion of cardiac output distributed to the right CCA remained relatively constant across gestation.


Abbreviations: ACABFV, anterior cerebral artery blood flow velocity; CCA, common carotid artery; LVO, left ventricular output; SVC, superior vena cava

Keywords: common carotid artery blood flow; cardiac output; Doppler ultrasound; reproducibility







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
ARCH DIS CHILD FETAL NEONATAL ED ED PRACTICE
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2006 BMJ Publishing Group Ltd & Royal College of Paediatrics and Child Health