Concentrations of vitamins A and E in amniotic fluid, extraembryonic coelomic fluid, and maternal serum in the first trimester of pregnancy.
Combined Department of Obstetrics, Gynaecology, and Reproductive Physiology, St Bartholomew's Hospital, London.
Paired samples of amniotic fluid and coelomic fluid were obtained by transvaginal ultrasound guided amniocentesis from 15 women with an ultrasonographically normal pregnancy between 8 and 12 weeks' gestation. Vitamins A and E were measured in the two pregnancy fluids and in maternal serum by high performance liquid chromatography with detection by ultraviolet absorption and fluorimetry respectively. Concentrations of vitamins A and E were higher in maternal serum than in coelomic fluid and were generally undetectable in amniotic fluid. All differences in concentration were significant. The vitamin E/cholesterol ratio was similar in maternal serum and coelomic fluid. No correlation was shown between the vitamin concentrations in the three fluids. These findings suggest that the coelomic cavity plays a part in the maternofetal exchange of these vitamins.
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.